Схема кухонной техники Other DAEWOO KOR-180A2A,KOR-181G2A,KOR-181H2A

Краткое описание

Формат файла: PDF

Полное описание

SAFETY AND PRECAUTIONS
CAUTION : This Device is to be Serviced Only by Properly Qualified Service Personnel. Consult the Service
Manual for Proper Service Procedures to Assure Continued Safety Operation and for Precautionsto be Taken to Avoid Possible Exposure to Excessive Microwave Energy.
1. FOR SAFE OPERATION
Damage that allows the microwave energy (that cooks or heats the food) to escape will result in poor cooking andmay cause serious bodily injury to the operator.IF ANY OF THE FOLLOWING CONDITIONS EXIST, OPERATOR MUST NOT USE THE APPLIANCE.(Only a trained service personnel should make repairs.)1) A broken door hinge.2) A broken door viewing screen.3) A broken front panel, oven cavity.4) A loosened door lock.5) A broken door lock.The door gasket plate and oven cavity surface should be kept clean.No grease, soil or spatter should be allowed to build up on these surfaces or inside the oven.DO NOT ATTEMPT TO OPERATE THIS APPLIANCE WITH THE DOOR OPEN. The microwave oven hasconcealed switches to make sure the power is turned off when the door is opened. Do not attempt to defeat them.DO NOT ATTEMPT TO SERVICE THIS APPLIANCE UNTIL YOU HAVE READ THIS SERVICE MANUAL.
2. FOR SAFE SERVICE PROCEDURES
1) If the oven is operative prior to servicing, a microwave emission check should be performed prior to servicing
2) If any certified oven unit is found to servicing, a microwave emission check should be performed prior to
servicing the oven.
(a) inform the manufacturer, importer or assembler,(b) repair the unit at no cost to the owner,(c) attempt to ascertain the cause of the excessive leakage,(d) tell the owner of the unit not to use the unit until the oven has been brought into compliance.
3) If the oven operates with the door open, the service person should tell the user not to operate the oven and
contact the manufacturer and CDRH immediately.
MICROWAVE RADIATION
PERSONNEL SHOULD NOT BE EXPOSED TO THE MICROWAVE ENERGY WHICH MAY RADIATEFROM THE MAGNETRON OR OTHER MICROWAVE GENERATING DEVICE IF IT IS IMPROPERLYUSED OR CONNECTED. ALL INPUT AND OUTPUT MICROWAVE CONNECTIONS. WAVEGUIDESFLANGES AND GASKETS MUST BE SECURED. NEVER OPERATE THE DEVICE WITHOUT AMICROWAVE ENERGY ABSORBING LOAD ATTACHED. NEVER LOOK INTO AN OPEN WAVEGUIDEOR ANTENNA WHILE THE DEVICE IS ENERGIZED.